*BURKERT solenoid valve first-class agent in China
German Baode Company attaches great importance to new product development and technological innovation. Through targeted product design, modernization and processing technology, strict and careful quality inspection, and practical market prediction, six series of products have been formed, mainly including “universal electromagnetic valve system”, “process control valve system”, “pneumatic control valve system”, “liquid analysis valve system”, and “sensor/transmitter” and “controller”. Baode products are also our main agent products. consulting service
*BURKERT solenoid valve first-class agent in China
Direct acting solenoid valve
Principle: When energized, the electromagnetic coil generates electromagnetic force to lift the closing member from the valve seat, and the valve opens; When the power is cut off, the electromagnetic force disappears, and the spring presses the closure against the valve seat, closing the valve.
Features: It can work normally under vacuum, negative pressure, and zero pressure, but the diameter generally does not exceed 25mm.
Step-by-step direct acting solenoid valve
Principle: It is a combination of direct action and pilot type. When there is no pressure difference between the inlet and outlet, after being energized, the electromagnetic force directly lifts the pilot small valve and the main valve closure upward in order to open the valve. When the inlet and outlet reach the starting pressure difference, after being energized, the electromagnetic force pilot the small valve, the pressure in the lower chamber of the main valve rises, and the pressure in the upper chamber decreases, thereby using the pressure difference to push the main valve upward; When power is cut off, the pilot valve uses spring force or medium pressure to push the closing member downward, causing the valve to close.
Features: It can also operate at zero differential pressure, vacuum, and high pressure, but with high power, it is required to be installed horizontally.
Pilot operated solenoid valve
Principle: When energized, electromagnetic force opens the pilot hole, causing the pressure in the upper chamber to rapidly drop, creating a high and low pressure difference around the closure. Fluid pressure pushes the closure upward, causing the valve to open; When the power is cut off, the spring force closes the pilot hole, and the inlet pressure rapidly forms a low to high pressure differential around the valve closing member through the bypass hole. The fluid pressure pushes the valve closing member downward to close the valve.
Features: The upper limit of the fluid pressure range is high, and can be installed arbitrarily (customized), but the fluid pressure differential condition must be met.
2. According to the differences in valve structure and material, as well as the differences in principle, electromagnetic valves are divided into six sub categories: direct acting diaphragm structure, step-by-step direct acting diaphragm structure, pilot diaphragm structure, direct acting piston structure, step-by-step direct acting piston structure, and pilot piston structure.
3. Solenoid valves are classified by function: water solenoid valve, steam solenoid valve, refrigeration solenoid valve, low-temperature solenoid valve, gas solenoid valve, fire solenoid valve, ammonia solenoid valve, gas solenoid valve, liquid solenoid valve, micro solenoid valve, pulse solenoid valve, hydraulic solenoid valve normally open solenoid valve, oil solenoid valve, DC solenoid valve, high-pressure solenoid valve, explosion-proof solenoid valve, etc.
Technical parameters of solenoid valve
Flow under valve seat (for gases and liquids)
Inner hole DN10-100
Valve body material: cast stainless steel 316L
Actuator material PA (PPS available on demand)
Sealing material PTFE (NBR, FKM, and EPDM available on demand)
Medium: water, alcohol, oil, fuel, salt solution, alkali solution, organic solvent
steam
Viscosity Max 600 mm2/s
Packing seal
(with silicone grease)
PTFE
Medium temperature ■ – 10 to+180 ° C, when PTFE sealed
ambient temperature
PA actuator ■
Actuator size<125
Actuator size Ø 175-225
PPS actuator
Actuator size Ø 40-80
Actuator size Ø 100-125
-10 to +60 °C
-10 to +50°C
+5 to +140 °C
+5 to+90 ° C, up to+140 ° C for short periods
Installation can be carried out as required, with the actuator facing upward
Control medium: neutral gas, air
Zui High Pilot Pressure
Actuator size Ø 40 – 80
Actuator size Ø 100
Actuator size Ø 100
Actuator size Ø 125
Actuator size Ø 175-225
PA and PPS 10 bar
PA 10 bar
PPS 7 bar
PA and PPS 7 bar
PA 6 bar
Shanghai agent of German original Baode BURKERT solenoid valve
control function
Inner aperture
[mm]connector
Actuator size
[mm]Kv value, water
[m3/h]Zui small pilot pressure
[bar]Zui at high temperature+180 ° C
Zui High Working Pressure
[bar]Order No
PA actuator
Flow under valve seat
A Two position two way, normally closed
(NC)
10 Flange 40 4.7 4.0 15 146 227
50 4.7 3.9 16 146 237
15 Flange 40 4.7 4.0 15 146 247
50 4.7 3.9 16 146 259
20 Flange 40 8.1 4.0 6.5 146 271
50 8.1 3.9 11 146 283
63 8.1 4.2 16 146 295
25 Flange 63 13.0 4.2 11 146 299
80 13.0 5.0 16 146 310
32 Flange 63 19.5 4.2 6 146 314
80 19.5 5.0 15 146 322
40 Flange 80 31.0 5.0 10 146 327
125 31.0 3.2 16 146 339
50 Flange 100 45.0 4.4 7.2 146 345
125 45.0 3.2 10 146 357
65 Flange 125 73.0 5.6 12 152 743
175 73.0 4.5 15 152 761
80 Flange 125 110.0 5.6 7.5 155 527
175 110.0 4.5 10 152 779
225 110.0 3.3 12.5 152 797
100 flange 125 165.0 5.6 5 155 546
175 155.0 4.5 7.0 152 815
225 155.0 4.8 10 152 833